D-optimal test scheme was presented for calibrating second-order coefficient K2 of PIGA (Pendulous Integrating Gyro Accelerometer) error model on a precision centrifuge with counter-rotating platform.
The paper presented a two-position test method for calibrating error model coefficients of PIGA (pendulous integrating gyro accelerometer) using precision centrifuge without counter-rotating platform.
提出了一种在不带有反转平台的精密离心机上标定陀螺加速度计误差模型系数的两位置测试方法。
The establishment of PIGA error model provides a theory basis to implement error compensation effectively and to raised precision of inertial system reliably.
陀螺加速度表的误差模型的建立对实现有效的误差补偿和可靠地提高惯性系统实用精度提供理论依据。
In this paper PIGA error model is established based on all-round effect of error factor for PIGA.